Blisstool LTC48X Guia do Utilizador Página 26

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 28
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 25
14.5. Settings for terrains with high degree of mineralization
<TDAVH> Terrain optimized setting in discrimination mode and automatic ground
balance for no contaminated terrains with high degree of mineralization:
VOLUME potentiometer: of level from „4“ to „8“
THRESHOLD potentiometer: two levels before the zoom level
GROUND switch: position „AUTO“
AUTO ZONES switch: position „1“ or „3
DISCR LEVEL potentiometer: at LTC48X v2 of level „5“, while at LTC48X v1 of level „10“
DISCR WIDTH potentiometer: at LTC48X v2 of level „NORM“, while at LTC48X v1 of level „2“
DISCR DEPTH potentiometer: of levels from „9“ to „10“
<TDGVH> Terrain optimized setting in discrimination mode and manual ground
balance for no contaminated terrains with high degree of mineralization:
VOLUME potentiometer: of level from „4“ to „8“
THRESHOLD potentiometer: two levels before the zoom level
GROUND switch: position „MANUAL“
GROUND potentiometer: level at which the metal detector is balanced to the terrain (usually
between levels from "3" to "7")
DISCR LEVEL potentiometer: at LTC48X v2 of level „5“, while at LTC48X v1 of level „10“
DISCR WIDTH potentiometer: at LTC48X v2 of level „NORM“, while at LTC48X v1 of level „2“
DISCR DEPTH potentiometer: of levels from „9“ to „10“
<TDACH> Terrain optimized setting in discrimination mode and automatic ground
balance for contaminated terrains with high degree of mineralization:
VOLUME potentiometer: of level from „4“ to „8“
THRESHOLD potentiometer: two levels before the zoom level
GROUND switch: position „AUTO“
AUTO ZONES switch: position „1“ or „3
DISCR LEVEL potentiometer: at LTC48X v2 of level „6“, while at LTC48X v1 of level „10“
DISCR WIDTH potentiometer: at LTC48X v2 of level „2“, while at LTC48X v1 of level „4“
DISCR DEPTH potentiometer: of level „10“
<TDGCH> Terrain optimized setting in discrimination mode and manual ground
balance for contaminated terrains with high degree of mineralization:
VOLUME potentiometer: of level from „4“ to „8“
THRESHOLD potentiometer: two levels before the zoom level
GROUND switch: position „MANUAL“
GROUND potentiometer: level at which the metal detector is balanced to the terrain (usually
between levels from "3" to "7")
DISCR LEVEL potentiometer: at LTC48X v2 of level „6“, while at LTC48X v1 of level „10“
DISCR WIDTH potentiometer: at LTC48X v2 of level „2“, while at LTC48X v1 of level „4“
DISCR DEPTH potentiometer: of level „10“
BLISSTOOL LTC48X - User Guide (version EN201008241400) Page 26 of 28
Vista de página 25
1 2 ... 21 22 23 24 25 26 27 28

Comentários a estes Manuais

Sem comentários